EL屏幕软件升级.ppt

上传人:豆**** 文档编号:26231833 上传时间:2022-07-16 格式:PPT 页数:34 大小:7.85MB
返回 下载 相关 举报
EL屏幕软件升级.ppt_第1页
第1页 / 共34页
EL屏幕软件升级.ppt_第2页
第2页 / 共34页
点击查看更多>>
资源描述

《EL屏幕软件升级.ppt》由会员分享,可在线阅读,更多相关《EL屏幕软件升级.ppt(34页珍藏版)》请在得力文库 - 分享文档赚钱的网站上搜索。

1、25.05.08Seite 2OL81/DIG000/DM4000Training overview :Interface structureHow to Start-up the new components 1. OP1000 (applicationsoftware) 2. DIG000 (applicationsoftware) 25.05.08Seite 3DIG000 with MasterLogic and OP1000 NetworkEthernetCan Group 07with other sensorsOL80FR.Fx.FE.Network 1DIG000 Softwa

2、re: Pc0016-8003M +Application software xxx.xxxPossible communicationsMitshubishiSiemensBeckhoff.Standard Ethernet: Software Pc0016-8002M Ethernet Ip Software Pc0016-8010M EGDOP 1000PLCEthernet SwitchX8; 24V DC (z.B. 326491) Can Group 07with other sensorsOL80FR.Fx.FE.Network 2DIG000DIG00025.05.08Seit

3、e 4How to Start-up the new componentsChange the PC-Ethernet settingsDownload Software to the DIG000Set the ip-address of the OP1000 PanelDownload software to the OP1000 PanelDownload PLC-software in DIG000Check the Dongle Value EK 5101 25.05.08Seite 5How to Start-up the new components1. Change the P

4、C-Ethernet settingsTo get a ethernet connection between two devices you need a few conditionsA ethernet connection exists of following parts. ip-address010.006.002.003Netmask255.255.000.000Gateway000.000.000.000Device 1ip-address010.006.002.124Netmask255.255.000.000Gateway000.000.000.000Device 2A co

5、nnection is only possible if the blue numbers are the same25.05.08Seite 6How to Start-up the new components1. Change the Pc-Ethernet settingsOpen the networksetting in your PC10 . 6 . 2 . 4To get a connection to the devicesSet the ip-address of the pc-ethernet cardTo a address like 10.6.x.xAttention

6、:If you connect a Pc direkt to a device you Need a cross-cabel.If the Pc and the devices are connected Over a ethernet switch you need a patch cabel.25.05.08Seite 7How to Start-up the new components1. Change the Pc-Ethernet settingsPut in the ip-addressOf the DiG000Open javacanmonpress the Add butto

7、n25.05.08Seite 8How to Start-up the new components1. Change the Pc-Ethernet settingsIf you dont know the ethernet address you have to set or read the ip-address1. With a seriell connection2. with Javacanmon Can-Dongle. recommended25.05.08Seite 9How to Start-up the new components1. Change the Pc-Ethe

8、rnet settingsChange to service,Select the Service functionSet TcpIp Addr andPress the buttonSet25.05.08Seite 10How to Start-up the new components1. Change the Pc-Ethernet settingsConnect the hardware to the PC.Ethernet (Cross cabel) z.B. 328927 (10m) 25.05.08Seite 11How to Start-up the new component

9、s1. Change the Pc-Ethernet settingsHere you see theActive connectionTo the hardware25.05.08Seite 12How to Start-up the new components2. Download software to the DIG000 or DM4000Basicsoftware: PC0016-8008M_ZBBasis MasterLogic: PC0016-8003M_ZDEhternet/IP: PC0016-8002M_ZCPress the Download buttonChange

10、 to Software25.05.08Seite 13How to Start-up the new components2. Download software to the DIG000 or DM4000Select the software and press openDownload is onlyPossible over Ethernet 25.05.08Seite 14How to Start-up the new components3. Set the Ip-address of the OP1000 PanelIf you press with your fingers

11、 at the same time these points for At least 2s. The panel switch to the setup mode25.05.08Seite 15How to Start-up the new componentsChange with the keyboard to the function CONFIG and press ENTERThe panel switch to the configuration mode3. Set the ip-address of the PanelENTER25.05.08Seite 16How to S

12、tart-up the new components3. Set the ip-address of the PanelIn the configuration mode You can see some informations.FirmwareNetworksettingsTimesettingskeyboard25.05.08Seite 17How to Start-up the new components3. Set the ip-address of the PanelIn the configuration mode You can see some informations.T

13、o change the Networksettings Touch this area.25.05.08Seite 18How to Start-up the new components3. Set the ip-address of the PanelSet the new ip-Address And press EnterSet the netmask and pressEnterSet the Gateway and pressEnterPress 2 time Enter and the New settings change.25.05.08Seite 19How to Sta

14、rt-up the new components3. Set the ip-address of the PanelConnect the OP1000 to the PC.Ethernet (Cross cabel) z.B. 328927 (10m) 25.05.08Seite 20How to Start-up the new componentsYou need the software UniDataexchanger from exor. Each application need a special panelsoftware named Project.romSelect Do

15、wnload ProjectSelect the Firmeware4. Download software to the panel 25.05.08Seite 21How to Start-up the new components4. Download software to the panel Open the optionCommunication To select the ip-addressOf the panel 25.05.08Seite 22How to Start-up the new componentsSelect the OP1000Here you have t

16、o be set the ip-address of the Panel. The Panel must connected to the PCYou also can try the ButtonPick UniOP. All connected Panels are showed and you Can select the needed panelIf no panel is showed in the Pick UniOP you have no connection4. Download software to the panel 25.05.08Seite 23How to Sta

17、rt-up the new componentsBefor you can download a programm the panel have to be switched to the configuration mode. Select Commands Switch to configuation mode,And wait until done. The panel shows a black screen with severalSettings of the panel. After that you can start withThe download of the softw

18、are.4. Download software to the panel 25.05.08Seite 24How to Start-up the new componentsPress the Start button and select the application.rom file. After Open the download starts4. Download software to the panel 25.05.08Seite 25How to Start-up the new componentsYou see the state of the download4. Do

19、wnload software to the panel 25.05.08Seite 26How to Start-up the new componentsAfter successful download you have to switch the panal back to the operation mode. You also can switch off the power supply of the panel.4. Download software to the panel 25.05.08Seite 27How to Start-up the new components

20、4. Download software to the panel The panel is only running if you have a masterLogic software in a DIG000 or aDM4000 and is connected to a MasterLogicStartwindow ifNot connected25.05.08Seite 28Basicsoftware: PC0016-8008M_ZCBasis MasterLogic: PC0016-8003M_ZDEhternet/IP: PC0016-8002M_ZCInfos about th

21、e software of the masterLogic softwareHow to Start-up the new components5. Download masterLogic-software to the DIG000Select the PLC bar25.05.08Seite 29application Softplc: Softinfo of the applicationsoftwareHow to Start-up the new components5. Download MasterLogic-software to the DIG00025.05.08Seit

22、e 302. Select software.PRG1. Press download button3. Start downloadHow to Start-up the new components5. Download plc-software to the DIG00025.05.08Seite 31How to Start-up the new components6. Check the Dongle value from the EK 5101 on a DIG000You can read the dongle if youPress the button CheckSelect the hardware.DiG000 DM4000DO8125.05.08Seite 32How to Start-up the new components6. Check the Dongle value from the EK 5101 on a DIG000The actuall connected dongleHas the dongle value 6 + MasterLogic software25.05.08Seite 33Thanks for your attention

展开阅读全文
相关资源
相关搜索

当前位置:首页 > 教育专区 > 教案示例

本站为文档C TO C交易模式,本站只提供存储空间、用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。本站仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知得利文库网,我们立即给予删除!客服QQ:136780468 微信:18945177775 电话:18904686070

工信部备案号:黑ICP备15003705号-8 |  经营许可证:黑B2-20190332号 |   黑公网安备:91230400333293403D

© 2020-2023 www.deliwenku.com 得利文库. All Rights Reserved 黑龙江转换宝科技有限公司 

黑龙江省互联网违法和不良信息举报
举报电话:0468-3380021 邮箱:hgswwxb@163.com