1、【精品文档】如有侵权,请联系网站删除,仅供学习与交流步进电机-英文资料及翻译(Stepping Motor Types).精品文档.Stepping Motor TypesIntroductionStepping motors come in two varieties, permanent magnet and variable reluctance (there are also hybrid motors, which are indistinguishable from permanent magnet motors from the controllers point of view

2、). Lacking a label on the motor, you can generally tell the two apart by feel when no power is applied. Permanent magnet motors tend to cog as you twist the rotor with your fingers, while variable reluctance motors almost spin freely (although they may cog slightly because of residual magnetization

3、in the rotor). You can also distinguish between the two varieties with an ohmmeter. Variable reluctance motors usually have three (sometimes four) windings, with a common return, while permanent magnet motors usually have two independent windings, with or without center taps. Center-tapped windings

4、are used in unipolar permanent magnet motors. Stepping motors come in a wide range of angular resolution. The coarsest motors typically turn 90 degrees per step, while high resolution permanent magnet motors are commonly able to handle 1.8 or even 0.72 degrees per step. With an appropriate controlle

5、r, most permanent magnet and hybrid motors can be run in half-steps, and some controllers can handle smaller fractional steps or microsteps. For both permanent magnet and variable reluctance stepping motors, if just one winding of the motor is energised, the rotor (under no load) will snap to a fixe

6、d angle and then hold that angle until the torque exceeds the holding torque of the motor, at which point, the rotor will turn, trying to hold at each successive equilibrium point. Variable Reluctance MotorsFigure 1.1 If your motor has three windings, typically connected as shown in the schematic di

7、agram in Figure 1.1, with one terminal common to all windings, it is most likely a variable reluctance stepping motor. In use, the common wire typically goes to the positive supply and the windings are energized in sequence.The cross section shown in Figure 1.1 is of 30 degree per step variable relu

8、ctance motor. The rotor in this motor has 4 teeth and the stator has 6 poles, with each winding wrapped around two opposite poles. With winding number 1 energised, the rotor teeth marked X are attracted to this windings poles. If the current through winding 1 is turned off and winding 2 is turned on

9、, the rotor will rotate 30 degrees clockwise so that the poles marked Y line up with the poles marked 2. To rotate this motor continuously, we just apply power to the 3 windings in sequence. Assuming positive logic, where a 1 means turning on the current through a motor winding, the following contro

10、l sequence will spin the motor illustrated in Figure 1.1 clockwise 24 steps or 2 revolutions: Winding 1 1001001001001001001001001 Winding 2 0100100100100100100100100 Winding 3 0010010010010010010010010 time -The section of this tutorial on Mid-Level Control provides details on methods for generating

11、 such sequences of control signals, while the section on Control Circuits discusses the power switching circuitry needed to drive the motor windings from such control sequences. There are also variable reluctance stepping motors with 4 and 5 windings, requiring 5 or 6 wires. The principle for drivin

12、g these motors is the same as that for the three winding variety, but it becomes important to work out the correct order to energise the windings to make the motor step nicely. The motor geometry illustrated in Figure 1.1, giving 30 degrees per step, uses the fewest number of rotor teeth and stator

13、poles that performs satisfactorily. Using more motor poles and more rotor teeth allows construction of motors with smaller step angle. Toothed faces on each pole and a correspondingly finely toothed rotor allows for step angles as small as a few degrees. Unipolar MotorsFigure 1.2 Unipolar stepping m

14、otors, both Permanent magnet and hybrid stepping motors with 5 or 6 wires are usually wired as shown in the schematic in Figure 1.2, with a center tap on each of two windings. In use, the center taps of the windings are typically wired to the positive supply, and the two ends of each winding are alt

15、ernately grounded to reverse the direction of the field provided by that winding. The motor cross section shown in Figure 1.2 is of a 30 degree per step permanent magnet or hybrid motor - the difference between these two motor types is not relevant at this level of abstraction. Motor winding number

16、1 is distributed between the top and bottom stator pole, while motor winding number 2 is distributed between the left and right motor poles. The rotor is a permanent magnet with 6 poles, 3 south and 3 north, arranged around its circumfrence. For higher angular resolutions, the rotor must have propor

17、tionally more poles. The 30 degree per step motor in the figure is one of the most common permanent magnet motor designs, although 15 and 7.5 degree per step motors are widely available. Permanent magnet motors with resolutions as good as 1.8 degrees per step are made, and hybrid motors are routinel

18、y built with 3.6 and 1.8 degrees per step, with resolutions as fine as 0.72 degrees per step available. As shown in the figure, the current flowing from the center tap of winding 1 to terminal a causes the top stator pole to be a north pole while the bottom stator pole is a south pole. This attracts

19、 the rotor into the position shown. If the power to winding 1 is removed and winding 2 is energised, the rotor will turn 30 degrees, or one step. To rotate the motor continuously, we just apply power to the two windings in sequence. Assuming positive logic, where a 1 means turning on the current thr

20、ough a motor winding, the following two control sequences will spin the motor illustrated in Figure 1.2 clockwise 24 steps or 2 revolutions: Winding 1a 1000100010001000100010001 Winding 1b 0010001000100010001000100 Winding 2a 0100010001000100010001000 Winding 2b 0001000100010001000100010 time -Windi

21、ng 1a 1100110011001100110011001 Winding 1b 0011001100110011001100110 Winding 2a 0110011001100110011001100 Winding 2b 1001100110011001100110011 time -Note that the two halves of each winding are never energized at the same time. Both sequences shown above will rotate a permanent magnet one step at a

22、time. The top sequence only powers one winding at a time, as illustrated in the figure above; thus, it uses less power. The bottom sequence involves powering two windings at a time and generally produces a torque about 1.4 times greater than the top sequence while using twice as much power. The sect

23、ion of this tutorial on Mid-Level Control provides details on methods for generating such sequences of control signals, while the section on Control Circuits discusses the power switching circuitry needed to drive the motor windings from such control sequences. The step positions produced by the two

24、 sequences above are not the same; as a result, combining the two sequences allows half stepping, with the motor stopping alternately at the positions indicated by one or the other sequence. The combined sequence is as follows: Winding 1a 11000001110000011100000111 Winding 1b 00011100000111000001110

25、000 Winding 2a 01110000011100000111000001 Winding 2b 00000111000001110000011100time -Bipolar MotorsFigure 1.3 Bipolar permanent magnet and hybrid motors are constructed with exactly the same mechanism as is used on unipolar motors, but the two windings are wired more simply, with no center taps. Thu

26、s, the motor itself is simpler but the drive circuitry needed to reverse the polarity of each pair of motor poles is more complex. The schematic in Figure 1.3 shows how such a motor is wired, while the motor cross section shown here is exactly the same as the cross section shown in Figure 1.2. The d

27、rive circuitry for such a motor requires an H-bridge control circuit for each winding; these are discussed in more detail in the section on Control Circuits. Briefly, an H-bridge allows the polarity of the power applied to each end of each winding to be controlled independently. The control sequence

28、s for single stepping such a motor are shown below, using + and - symbols to indicate the polarity of the power applied to each motor terminal: Terminal 1a +-+-+-+- +-+-+-+- Terminal 1b -+-+-+-+- -+-+-+-+ Terminal 2a -+-+-+-+- -+-+-+-+- Terminal 2b -+-+-+-+ +-+-+-+-+ time -Note that these sequences

29、are identical to those for a unipolar permanent magnet motor, at an abstract level, and that above the level of the H-bridge power switching electronics, the control systems for the two types of motor can be identical. Note that many full H-bridge driver chips have one control input to enable the ou

30、tput and another to control the direction. Given two such bridge chips, one per winding, the following control sequences will spin the motor identically to the control sequences given above: Enable 1 1010101010101010 1111111111111111 Direction 1 1x0x1x0x1x0x1x0x 1100110011001100 Enable 2 01010101010

31、10101 1111111111111111 Direction 2 x1x0x1x0x1x0x1x0 0110011001100110 time -To distinguish a bipolar permanent magnet motor from other 4 wire motors, measure the resistances between the different terminals. It is worth noting that some permanent magnet stepping motors have 4 independent windings, org

32、anized as two sets of two. Within each set, if the two windings are wired in series, the result can be used as a high voltage bipolar motor. If they are wired in parallel, the result can be used as a low voltage bipolar motor. If they are wired in series with a center tap, the result can be used as

33、a low voltage unipolar motor. Bifilar MotorsBifilar windings on a stepping motor are applied to the same rotor and stator geometry as a bipolar motor, but instead of winding each coil in the stator with a single wire, two wires are wound in parallel with each other. As a result, the motor has 8 wire

34、s, not four. In practice, motors with bifilar windings are always powered as either unipolar or bipolar motors. Figure 1.4 shows the alternative connections to the windings of such a motor. Figure 1.4 To use a bifilar motor as a unipolar motor, the two wires of each winding are connected in series a

35、nd the point of connection is used as a center-tap. Winding 1 in Figure 1.4 is shown connected this way. To use a bifilar motor as a bipolar motor, the two wires of each winding are connected either in parallel or in series. Winding 2 in Figure 1.4 is shown with a parallel connection; this allows lo

36、w voltage high-current operation. Winding 1 in Figure 1.4 is shown with a series connection; if the center tap is ignored, this allows operation at a higher voltage and lower current than would be used with the windings in parallel. It should be noted that essentially all 6-wire motors sold for bipo

37、lar use are actually wound using bifilar windings, so that the external connection that serves as a center tap is actually connected as shown for winding 1 in Figure 1.4. Naturally, therefore, any unipolar motor may be used as a bipolar motor at twice the rated voltage and half the rated current as

38、is given on the nameplate. The question of the correct operating voltage for a bipolar motor run as a unipolar motor, or for a bifilar motor with the motor windings in series is not as trivial as it might first appear. There are three issues: The current carrying capacity of the wire, cooling the mo

39、tor, and avoiding driving the motors magnetic circuits into saturation. Thermal considerations suggest that, if the windings are wired in series, the voltage should only be raised by the square root of 2. The magnetic field in the motor depends on the number of ampere turns; when the two half-windin

40、gs are run in series, the number of turns is doubled, but because a well-designed motor has magnetic circuits that are close to saturation when the motor is run at its rated voltage and current, increasing the number of ampere-turns does not make the field any stronger. Therefore, when a motor is ru

41、n with the two half-windings in series, the current should be halved in order to avoid saturation; or, in other words, the voltage across the motor winding should be the same as it was. For those who salvage old motors, finding an 8-wire motor poses a challenge! Which of the 8 wires is which? It is

42、not hard to figure this out using an ohm meter, an AC volt meter, and a low voltage AC source. First, use the ohm meter to identify the motor leads that are connected to each other through the motor windings. Then, connect a low-voltage AC source to one of these windings. The AC voltage should be be

43、low the advertised operating voltage of the motor; voltages under 1 volt are recommended. The geometry of the magnetic circuits of the motor guarantees that the two wires of a bifilar winding will be strongly coupled for AC signals, while there should be almost no coupling to the other two wires. Th

44、erefore, probing with an AC volt meter should disclose which of the other three windings is paired to the winding under power. Multiphase MotorsFigure 1.5 A less common class of permanent magnet or hybrid stepping motor is wired with all windings of the motor in a cyclic series, with one tap between

45、 each pair of windings in the cycle, or with only one end of each motor winding exposed while the other ends of each winding are tied together to an inaccessible internal connection. In the context of 3-phase motors, these configurations would be described as Delta and Y configurations, but they are

46、 also used with 5-phase motors, as illustrated in Figure 1.5. Some multiphase motors expose all ends of all motor windings, leaving it to the user to decide between the Delta and Y configurations, or alternatively, allowing each winding to be driven independently. Control of either one of these mult

47、iphase motors in either the Delta or Y configuration requires 1/2 of an H-bridge for each motor terminal. It is noteworthy that 5-phase motors have the potential of delivering more torque from a given package size because all or all but one of the motor windings are energised at every point in the d

48、rive cycle. Some 5-phase motors have high resolutions on the order of 0.72 degrees per step (500 steps per revolution). Many automotive alternators are built using a 3-phase hybrid geometry with either a permanent magnet rotor or an electromagnet rotor powered through a pair of slip-rings. These have been successfully used as stepping motors in some heavy duty industrial applications; step angles of 10 degrees per step have been reported. With a 5-phase motor, there are 10 steps per repeat in the stepping cycle, as shown below: Terminal 1 +-+-+ Terminal 2 -+-+- Termin

展开阅读全文
相关资源
相关搜索

当前位置:首页 > 教育专区 > 小学资料

本站为文档C TO C交易模式,本站只提供存储空间、用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。本站仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知得利文库网,我们立即给予删除!客服QQ:136780468 微信:18945177775 电话:18904686070

工信部备案号:黑ICP备15003705号-8 |  经营许可证:黑B2-20190332号 |   黑公网安备:91230400333293403D

© 2020-2023 www.deliwenku.com 得利文库. All Rights Reserved 黑龙江转换宝科技有限公司 

黑龙江省互联网违法和不良信息举报
举报电话:0468-3380021 邮箱:hgswwxb@163.com